EM4200 vs EM4305 vs T5577

EM4200 vs EM4305 vs T5577: 125 kHz Read-Only vs Rewritable RFID Chips

"125 kHz" names an inductive frequency band, not one compatible chip. EM4200 (EM Microelectronic's replacement for EM4100 and TK4100) transmits a permanent, laser-programmed 64-bit ID with zero write commands. EM4305 and Microchip's ATA5577C (T5577) are both rewritable 125 kHz chips, yet they use completely different write protocols, modulations and password models — so an LF encoder built for one often cannot program the other.

Key points

Factory ROM vs rewritable EEPROM

EM4200 (and TK4100) broadcast a fixed 64-bit EM4100 ID forever. EM4305 and T5577 store rewritable EEPROM blocks configured over the 125 kHz field.

Different LF writer protocols

EM4305 follows EM4469/4569 commands with Manchester or Bi-phase output only. T5577 (ATA5577C) uses its own Block 0 register and adds FSK, PSK and NRZ.

Memory locks are not encryption

Passwords and lock bits stop RF overwriting on the card itself, not air-interface replay. If credential cloning carries real risk, upgrade to 13.56 MHz AES.

Which 125 kHz chip should you specify?

Match the chip to two things: what your installed wall readers decode, and whether your issuing workflow writes to the card. Ordering a rewritable blank when your software only whitelists factory UIDs adds cost and configuration risk; ordering read-only cards when your front-desk or lock encoder writes site data causes every write to fail.

Choose [EM4200](/product/em4200-card/) (in its `Manchester 64` access version, which directly replaces older EM4100/4102 and TK4100 cards) when your door controller, attendance clock or parking barrier simply enrols a permanent 64-bit EM-format number. Choose [EM4305](/product/em4305-card/) (genuine EM Microelectronic silicon) when your encoder explicitly specifies EM4205/4305 commands, needs a write-only 32-bit password that can never be read back over RF, or requires `Reader Talk First`. Choose [T5577](/product/t5577-card/) (genuine Microchip `ATA5577C`, compatible with Atmel T5557/ATA5567) when one rewritable blank must support FSK, PSK, Manchester or Bi-phase credential formats, or endure frequent rewrites (`100,000` minimum cycles vs `1,000` on EM4305).

If an existing installation instead specifies NXP's proprietary 125 kHz challenge-response family, see [HITAG 2 cards](/product/hitag-2-card/), and see [125 kHz RFID cards](/product/125-khz-rfid-card/), [proximity key fobs](/product/proximity-fobs/) and [125 kHz RFID stickers](/product/125khz-rfid-sticker/) for form-factor options.

EM4200 vs EM4305 vs T5577 (ATA5577C): datasheet comparison

All silicon figures below come from EM Microelectronic's public EM4200 and EM4205/EM4305 data sheet (v6.0) and Microchip's ATA5577C data sheet (DS70005357B). Chip ratings describe the IC; finished read distance depends on coil geometry and your reader:

SpecificationEM4200 (EM4100 / TK4100 class)EM4305 (EM Microelectronic)T5577 (Microchip ATA5577C)
Read / write capabilityRead-only (laser-programmed ROM at wafer)Read / write EEPROMRead / write EEPROM
Total memory layout128-bit ROM (access mask sends 64-bit frame)512 bits: 16 words × 32 bits363 bits: 11 blocks × 33 bits (1 lock + 32 data)
Usable regular-read payloadFixed 64-bit EM4100 frame (40 ID bits + header/parity)Up to 288 bits (Words 5–13; Words 0 & 3 command-only)Up to 224 bits (Page 0 Blocks 1–7; 192 bits if Block 7 holds password)
Supported modulationsManchester (64-bit access mask)Manchester or Bi-phase onlyDirect/NRZ, Manchester, Bi-phase, Diff. Bi-phase (X-mode), FSK1/2/1a/2a, PSK1/2/3
Supported data ratesRF/64 on standard Manchester 64 access maskRF/8, RF/16, RF/32, RF/64 (plus RF/40 on 330 pF)Basic: 8 rates RF/8..RF/128; X-mode: any even rate RF/2..RF/128
Password architectureNone (immutable ROM)Write-only 32-bit password in Word 2 (never broadcast); Read & Write LoginOptional 32-bit password in Page 0 Block 7 (broadcasts if MAXBLK = 7!)
Silent / command-first modeNone (Tag Talks First continuously)Reader Talk First (RTF) option in Word 4Answer-On-Request (AOR) wake-up carrying 32-bit password
Permanent write lockingFactory-immutable ROMWords 14–15 protection bits lock Words 0–131 permanent lock bit per block + global OTP bit in Block 0
Write endurance (datasheet min.)Not applicable (read-only)1,000 write cycles; 10 years at 55 °C100,000 erase/write cycles; 10 years at 55 °C

Check these options against your system →

Three engineering traps that break 125 kHz encoding batches

Even experienced integrators hit compatibility surprises when switching between EM4305 and T5577 or pre-encoding EM4100 IDs. Watch for these three datasheet details before locking a specification:

  1. The Bi-phase naming inversion: In EM Microelectronic's EM4305 datasheet, *Bi-phase* places the extra mid-bit transition on a logic `0`. In Microchip's ATA5577C datasheet, plain *Bi-phase* places the extra transition on a logic `1`, while EM's `0`-transition coding is called *Differential Bi-phase* (an Extended Mode option). Copying "Bi-phase" by name between the two chips produces unreadable waveforms.
  2. Broadcasting the T5577 password by mistake: On EM4305, `Word 2` is hardware write-only and never enters the default read loop. On T5577, `Page 0 Block 7` is an ordinary user block repurposed as the 32-bit password when `PWD = 1`. If `MAXBLK` is left at `7`, the T5577 transmits its own secret password over the air on every read. Check your Block 0 hex in our T5577 Block 0 & EM4100 Calculator before programming.
  3. Printed card number vs reader Wiegand output: A 64-bit EM4100 frame carries an 8-bit version/customer byte plus a 32-bit ID, yet access panels display that same chip as 10-digit decimal (`10D`), 8-digit decimal (`8D`) or 26-bit Wiegand (`3D` facility + `5D` card number). Verify your controller's exact output format in our RFID UID & Wiegand Format Converter and specify which format should be printed or laser-engraved on the card or fob.

How EM4305 and T5577 emulate the 64-bit EM4100 format

Because a legacy 125 kHz EM reader has no challenge-response handshake and simply demodulates incoming 125 kHz amplitude changes, all three chips can present the same 64-bit EM4100 bit stream (9 header `1`s, ten 4-bit data nibbles each followed by an even row-parity bit, four even column-parity bits, and a `0` stop bit):

An EM4200 (`Manchester 64` mask) outputs those 64 bits permanently from ROM as soon as it enters the field. An EM4305 configured in `Word 4` for Manchester at `RF/64` with `Word 6` as the last default-read word loops the 64 bits stored in `Words 5–6` (note that fresh EM4305 silicon arrives from EM configured for 128-bit `RF/32` Bi-phase FDX-B coding, so `Word 4` must be written before EM4100 use). A T5577 configured in `Page 0 Block 0` for Basic Mode Manchester at `RF/64` with `MAXBLK = 2` and `ST = 0` (`00148040h`) loops the 64 bits stored in `Blocks 1–2`.

Note on 134.2 kHz ISO 11784/11785 animal ID: although both EM4305 and ATA5577C datasheets support `FDX-B` bit coding across the 100–150 kHz IC range, official animal transponders operate at 134.2 kHz with resonant coils tuned to that carrier and are subject to ICAR and national veterinary device rules. Standard 125 kHz access cards and fobs are not animal-identification devices.

Security boundary: when to stay on 125 kHz and when to move to 13.56 MHz

Be clear with stakeholders about what 125 kHz passwords and lock bits actually protect. Setting an EM4305 password (`Word 2`) or T5577 password (`Block 7` with `MAXBLK < 7`) and setting permanent lock bits stops someone overwriting your card, which prevents tampering on issued badges. Neither stops a handheld LF cloner from recording the unencrypted 64-bit or FSK/PSK waveform in the air and writing that exact bit stream onto a fresh T5577 blank.

Keep 125 kHz when matching an installed LF reader estate where convenience, cost and backward compatibility outweigh cloning risk. When building a new access system or closing a cloning vulnerability found in an audit, move readers and credentials to 13.56 MHz mutual AES-128 authentication — compare MIFARE Classic vs Plus vs DESFire and our access-control key fob and card guide. During a multi-building transition, dual-frequency combi cards or fobs carrying both a 125 kHz coil and a 13.56 MHz DESFire EV3 chip let users carry one credential across old and new doors.

Published 2026-11-26 · Updated 2026-11-26

Frequently asked questions

Are TK4100, EM4100 and EM4200 interchangeable on 125 kHz readers?

For standard 64-bit EM-format access readers, yes: EM Microelectronic designed the EM4200 (in its Manchester 64 access mask) as the direct, higher-range drop-in replacement for the discontinued EM4100/4102, and TK4100 is a compatible read-only 64-bit clone format. Proud Tek builds its EM4100-compatible read-only cards on genuine EM4200 silicon; always specify the 64-bit Manchester access version rather than the 128-bit animal-ID mask, and test a sample on your reader.

Can an EM4305 writer program a T5577 card, or vice versa?

Only if the desktop LF writer hardware and software explicitly implement both chip protocols. EM4305 uses EM4469/4569 Login, Write Word and Protect commands over a 16-word memory map, whereas T5577 (Microchip ATA5577C) uses 33-bit block-write opcodes governed by Page 0 Block 0. Once programmed to output the 64-bit EM4100 Manchester frame at RF/64, however, both cards look identical to a read-only EM4100 wall reader.

Why does EM4305 have 1,000 write cycles while T5577 has 100,000?

Those are the respective minimum endurance figures published by EM Microelectronic (4205-4305-DS-01) and Microchip (DS70005357B), both with 10-year data retention at 55 °C. For access badges or key fobs written once at issuance and occasionally re-issued to new staff, 1,000 write cycles is plenty; if an industrial or leisure system rewrites data on the card on every transaction, specify T5577 (or move to 13.56 MHz).

Does setting a password or lock bit on T5577 or EM4305 stop card cloning?

No. Passwords and lock bits protect the chip's EEPROM from being overwritten or altered in the field. Because regular-read 125 kHz proximity formats broadcast static bits without cryptographic challenge-response, any device that captures the RF waveform can write the same static bits onto another blank card. Preventing credential cloning requires migrating readers and cards to cryptographic authentication such as MIFARE DESFire EV3.

Can smartphones (iPhone or Android) read 125 kHz EM4200, EM4305 or T5577 cards?

No. Smartphone NFC operates exclusively at 13.56 MHz (ISO/IEC 14443 and ISO/IEC 15693). No iPhone or Android phone has a 125 kHz inductive front end. If your project requires phone taps alongside legacy 125 kHz doors, specify a dual-frequency card or key fob combining a 125 kHz chip with an NTAG213 or DESFire EV3 13.56 MHz chip.

What should we include when ordering pre-encoded or numbered 125 kHz cards or fobs?

Send the required chip (EM4200, EM4305 or ATA5577C T5577), target output format (for example 64-bit EM4100 Manchester RF/64, or custom Block 0 settings), ID numbering range, printed number format (such as 10D, 8H10D or Wiegand 3D+5D), and whether password or write-lock bits should be set after encoding. Never send secret passwords in a public web form; agree password handover separately.

Qualify EM4200, EM4305 or T5577 samples on your equipment

Tell us your installed reader and LF encoder models, whether you need read-only or rewritable cards, key fobs or stickers, and your sample and production quantities. We reply and quote workable specifications within one business day.

Request 125 kHz samples or quote

Prefer to message us? WhatsApp or email about EM4200 vs EM4305 vs T5577: 125 kHz Read-Only vs Rewritable RFID Chips.